top of page

Fire Sprinkler Systems

At Quality Fire Protection Inc., we specialize in the design, installation, and maintenance of fire sprinkler systems that fully comply with NFPA 25 standards, ensuring your building meets all safety and code requirements. 

All fire protection systems are inspected, tested, and maintained in accordance with NFPA 25 - the Standard for the Inspection, Testing, and Maintenance of Water Based

Fire Protection Systems.

Wet Pipe Systems

Wet pipe systems are the most common and reliable type of fire sprinkler system. The pipes are constantly filled with water, allowing for instant activation when heat opens a sprinkler head. They provide fast response, simple operation, and easy to maintain through inspections and waterflow testing. Routine inspections, valve checks, and waterflow testing are performed to maintain compliance with NFPA 25 and ensure consistent performance.

2

Dry Pipe Systems 

Dry pipe systems are designed for areas exposed to freezing temperatures. Instead of water, the pipes are filled with pressurized air that holds a dry pipe valve closed. When a sprinkler head is activated, the air pressure drops, releasing water into the system. This design prevents frozen or burst pipes while delivering reliable fire protection in cold environments, in compliance with

NFPA 25 standards.

3

Pre-Action Systems

Pre-action systems combine the reliability of wet systems with the freeze protection of dry systems, providing extra protection. Water is held back by a valve until a fire detection device signals activation, reducing the risk of accidental discharge and minimizing water damage in sensitive areas. All routine testing and verification of detection devices and control valves ensure full NFPA 25 compliance.

4

Standpipe Systems

Standpipe systems provide hose connections throughout high-rise and

large commercial buildings, allowing firefighters immediate access to water during an emergency. Regular inspections and testing that cover valve operation, pressure levels, and flow performance are conducted in accordance with NFPA 25 order to maintain full operational performance and reliability.

Fire Sprinkler Installation

​

​

Design-Build Sprinkler Systems:

For new construction projects, Quality Fire Protection, Inc. provides complete design-build services. Our team handles the full process from engineering the fire sprinkler layout to installing the entire system ensuring the finished building is fully compliant, efficient, and tailored to the project’s specifications.

​

Sprinkler System Retrofits:
As fire codes evolve, many existing structures are now required to upgrade or add sprinkler systems. Our technicians are experienced in performing retrofit work in occupied buildings, minimizing disruption while bringing the system up to current safety standards and NFPA requirements.

​

Sprinkler Head Relocation:
Interior renovations such as new walls, ceiling changes, or tenant build outs often require sprinkler heads to be repositioned for proper coverage. We evaluate the updated layout, determine required adjustments, and relocate sprinklers to maintain full protection and code compliance.

​

Sprinkler Head Replacement:
Sprinkler heads must be tested and replaced when they reach 50 years of service or if they are part of a manufacturer recall. Many older residential and commercial buildings still contain recalled or outdated sprinkler heads, which significantly increase the risk of failure during a fire. Quality Fire Protection, Inc. provides full inspection and replacement services to ensure every head is reliable and ready to perform.

Quality Fire Protection, Inc.

Fire Sprinkler Inspection

  • NFPA 25 Inspections: Annual, quarterly, and monthly system checks.

  • Flow & Pressure Tests: Verify water supply and system performance.

  • Code Compliance: Identify deficiencies and provide correction plans.

  • Digital Reports: Clear documentation of all findings.

Fire Sprinkler Maintenance

  • Routine Service: Preventive care to keep systems reliable.

  • Repairs: Fix leaks, damaged heads, valves, and system issues.

  • System Upgrades: Modernize older systems for better performance.

  • Optimization: Ensure proper pressure, coverage, and readiness.

Fire Sprinkler Design

  • Custom Layouts: Engineered designs for any occupancy or hazard level.

  • CAD/BIM Models: Accurate digital plans for smooth installation.

  • NFPA Compliance: Every design meets national and local codes.

  • New Builds & Renovations: Scalable solutions for any project size.

Red Pipes and Sprinklers

Custom System Engineering:
Quality Fire Protection, Inc. provides fully engineered fire sprinkler designs tailored to each building’s occupancy, layout, and hazard classification. Every system is planned to deliver reliable performance and meet all applicable codes.

CAD and BIM Modeling:
Our design team uses advanced CAD and BIM software to produce accurate, coordinated drawings. These models streamline installation, reduce conflicts, and ensure efficient construction timelines.

Code & NFPA Compliance:
All designs follow NFPA standards, local fire marshal requirements, and building codes. We ensure every detail aligns with current regulations for seamless approval and long-term safety.

New Construction & Renovation Projects:
From ground-up builds to interior renovations, we provide scalable design solutions for commercial, industrial, and residential applications.

​

Comprehensive NFPA 25 Inspections:
Quality Fire Protection, Inc. conducts annual, quarterly, and monthly inspections to verify system readiness. Our technicians thoroughly check valves, gauges, alarms, and components in accordance with NFPA 25.

Flow, Pressure & Performance Testing:
We perform flow tests, main drain tests, and pressure evaluations to ensure the water supply and system function as intended during an emergency.

Preventive Maintenance & Repairs:
Routine maintenance helps prevent failures and extends system life. We repair leaks, replace damaged heads, service valves, and address any deficiencies identified during inspections.

Detailed Reports & Code Compliance:
Following each inspection, we provide clear digital reports outlining findings, required corrections, and recommendations. Our team ensures your system remains fully compliant with all local and national fire safety standards.

© 2001–2025 Quality Fire Protection, Inc. | 930 Kenner Ave., Kenner, LA 70062 | Licensed in LA, MS, AL, GA, FL.